Specifications:

Frequency Coverage (5 bands):
10 MHz to 400 MHz
Input/Output Impedance:
50 Ω

Inband RF Power Handling:

refer to chart
Inband Third Order Intercept Point:
+50 dBm (input)
Inband Second Order Intercept Point:
+100 dBm (input)
Tuning Control:
8 bit parallel
Tuning Speed:
20 µS
DC Power:

+5 VDC @ 400 mA to 1.5 A

Operating Temperature Range:
-40 to + 65°C
Center Frequency Drift:
80 PPM/°C
 Size (in/mm): 2.6 x 3.0 x 4.0 / 66.7 x 76.2 x 101.6
 Weight (ozs/kg): 18.7 / .5

The POWER-POLE® Series of tunable filters provides improved RF performance with increased power handling capability and the lowest insertion loss for a given bandwidth. The product line includes several standard designs in various frequencies to support almost any application. Approximate performance is summarized in the Power-Pole Series Selection Guide.

Performance:

The following plots illustrate approximate performance (not representative of all frequency ranges):

The following plots illustrate approximate insertion loss and bandwidth trends across a given frequency band, and the differences between various bands:

POWER-30-90-3  

POWER-225-400-4   

The following plot illustrates RF power handling vs. % bandwidth:

Important Application Notes:

  1. While changing RF center frequencies, RF input power must be reduced to < +20 dBm.  These filters will not support “Hot RF Switching Conditions”.  Please contact the factory in regards to custom features.
  2. Maximum strobe rate is 2kHz; Actual rate is dependent upon frequency band.

 

Power-Pole Series Selection Guide:

This Selection Guide illustrates approximate performance for the POWER-POLE Series.  Please note that our ‘Standard’ filters are shown highlighted.  Table values are shown as average/maximum.

Frequency Range

Suffix
Insertion Loss
% Bandwidth (3dB)
Power Handling

Shape Factor (30 dB / 3 dB)Overall Low Side High Side

Ultimate (2 x fo)

10 to 30
MHz
-1
 
 
 
 
 
 
 
-2
 
 
 
 
 
 
 
-3
 
 
-4
 
 
 
 
 
 
 
-5
 
 
 
 
 
 
 
30 to 90
MHz
-1
0.8/1.2
8.4/9.5
 
 
 
 
 
-2
1.6/2.4
4.3/4.8
 
6.9/7.6
9.3/10.4
4.5/4.7
 
-3
2.9/4.3
2.8/3.2
 
6.0/6.9
7.0/8.9
5.0/5.8
 
-4
3.4/4.6
2.2/2.5
 
 
 
 
 
-5
4.4/5.8
1.8/1.9
 
 
 
 
 
90 to 200
MHz
-1
0.8/1.2
8.6/9.2
 
6.0/6.5
7.5/8.3
4.6/4.7
 
-2
1.2/2.3
4.2/4.8
 
 
 
 
 
-3
 2.2/3.5
 2.7/3.2
 
 
 
 
 
-4
 3.3/5.0
 2.2/2.5
 
 
 
 
 
-5
 4.0/5.5
 1.8/2.0
 
 
 
 
 
200 to 400
MHz
-1
 
 
 
 
 
 
 
-2
1.3/2.2
4.2/4.8
 
5.6/6.1
6.4/7.0
4.8/5.3
 
-3
1.7/3.5
2.7/3.1
 
 
 
 
 
-4
 2.4/3.8
 2.2/2.5
 
 
 
 
 
-5
 
 
 
 
 
 
 
225 to 400
MHz
-1
0.6/0.9
8.2/9.1
 
5.8/6.0
7.0/7.3
4.6/4.7
 
-2
1.0/2.2
4.2/4.8
 
 
 
 
 
-3
1.7/3.2
2.7/3.1
 
 
 
 
 
-4
2.3/3.8
2.1/2.5
 
5.7/6.3
6.1/7.0
5.3/5.7
 
-5
2.5/4.2
1.8/2.0
 
5.9/6.2
6.4/6.2
5.4/5.8
 


Part Number Selection Guide:

Available Options:

B. Serial Interface
C. Custom Frequency Bands (Specify START and STOP frequencies in MHz)

Interface and Control Options:

Frequency Tuning Address

Power-Pole Series filters utilize an eight-bit scheme for tune words to digitally control tuning of the center frequency.  There are 250 equally spaced tuning increments across each standard filter band, resulting in 251 tune words from 00000000 to 11111010. The last 5 tune words are reserved for housekeeping functions. For further information on how to calculate tune words, please see the Frequency Tuning Address Application Note.

Interface Options

The filter comes standard with an 8-bit parallel interface, although a serial interface can be specified as an option.

DC Control Interface Characteristics

Switching Characteristics

Vcc = +5VDC, ± 10%; T= -40°C to +85°C

 

Strobe 

The filter is tuned within 15µS to the frequency designated by the tuneword existing on the eight control bit lines when the STB line is brought low.  Once strobed, data existing on the tune control lines is ignored until strobed again.  Maximum strobe rate is 2 kHz; Actual rate is dependent upon frequency band.

Temperature Effects 

Over the –40 to +65°C temperature range, filters will exhibit a temperature drift of less than 80 PPM/°C, or a total of less than ±0.5% of the center frequency.

Package Outline:

 

Pinout and Ratings:

 

Data is believed to be accurate. All data is subject to change without notice.

 
5558 Union Centre Drive • West Chester • Ohio 45069 USA • Phone: (513) 870-9060 • Fax: (513) 870-9064 • Email: support@polezero.com