Chip Select/Load
The filter is tuned to the frequency designated by the tuneword sent on the Serial Data In (SDI) control line, which is clocked in by the Serial Clock (SCK) line most significant bit (MSB) first while the Chip Select/Load ( ) line is held low. After the tuneword is sent, the filter is tuned by returning the Chip Select/Load line high. Maximum clock rate for SCK is 2 MHz and tune time is <100 mS.
RF Power Handling Capability
The filters are designed to operate with RF input power levels up to 250 milliwatts inband. Signals in the filter stopband up to 5 Watts at the input will not cause damage to the filter.
Temperature Effects
Over the –40 to +70°C temperature range, filters will exhibit a temperature drift of less than 80 PPM/°C, or a total of less than ±0.5% of the center frequency. |